homeapartmentpencilmagic-wanddroplighterpoopsunmooncloudcloud-uploadcloud-downloadcloud-synccloud-checkdatabaselockcogtrashdiceheartstarstar-halfstar-emptyflagenvelopepaperclipinboxeyeprinterfile-emptyfile-addenterexitgraduation-hatlicensemusic-notefilm-playcamera-videocamerapicturebookbookmarkuserusersshirtstorecarttagphone-handsetphonepushpinmap-markermaplocationcalendar-fullkeyboardspell-checkscreensmartphonetabletlaptoplaptop-phonepower-switchbubbleheart-pulseconstructionpie-chartchart-barsgiftdiamondlineariconsdinnercoffee-cupleafpawrocketbriefcasebuscartrainbicyclewheelchairselectearthsmilesadneutralmustachealarmbullhornvolume-highvolume-mediumvolume-lowvolumemichourglassundoredosynchistoryclockdownloaduploadenter-downexit-upbugcodelinkunlinkthumbs-upthumbs-downmagnifiercrossmenulistchevron-upchevron-downchevron-leftchevron-rightarrow-uparrow-downarrow-leftarrow-rightmovewarningquestion-circlemenu-circlecheckmark-circlecross-circleplus-circlecircle-minusarrow-up-circlearrow-down-circlearrow-left-circlearrow-right-circlechevron-up-circlechevron-down-circlechevron-left-circlechevron-right-circlecropframe-expandframe-contractlayersfunneltext-formattext-format-removetext-sizebolditalicunderlinestrikethroughhighlighttext-align-lefttext-align-centertext-align-righttext-align-justifyline-spacingindent-increaseindent-decreasepilcrowdirection-ltrdirection-rtlpage-breaksort-alpha-ascsort-amount-aschandpointer-uppointer-rightpointer-downpointer-left

Angled RJ45 Modules make Installation a lot easier

The data cable does not always enter the outlet from the right direction. Angled RJ45 modules with variable cable entry easily adapt to the direction the cable comes from. This saves time and nerves and avoides kinked cables.

 

RJ45 modules with a straight cable entry can be used in module carriers with straight or sloped RJ45 jacks only when the cable comes directly from behind or from the top. In installations where the cable enters the outlet from below, from the left or from the right, there is very often not enough space for proper cable routing left. This is especially true with shallow cable raceways and with flush-mount outlets. The result is transmission problems due to kinded cables.

The cable entry of innovative, angled RJ45 modules can be rotated in steps of 90 degrees on site. This enables cable entry from the right, from the left, from the top and from below, which in turn makes installation in confined spaces, flush-mount installation and installion behind wall panels much easier and in some cases possible at all.

Modules with a straight cable inlet are only suitable for cable entry from above in angled outlet boxes. With the AMJ-SL 4x90, cable entry is possible from below.

If the cable is inserted into the appliance installation box from below, there is not enough space for the cable in modules with a straight entry in angled outlet boxes: 
This results in transmission problems due to kinked cables. The AMJ-SL 4x90 gives the cable the space it needs.

For straight outlet boxes with modules, the cable can be fed in from above, below, right or left. The AMJ-SL 4x90 therefore offers enormous flexibility for installations in cavity walls and behind panelling of all kinds, which cannot be achieved with RJ45 modules with a fixed straight feed.

Installing the new AMJ-SL 4x90 is particularly easy: The wire manager enters the module housing always in the same direction and the cable entry part of the module is attached depending on the direction the cable comes from. Markings on the module housing and the cable entry part make it as easy as 1-2-3. And the proven SafeLock security locking mechanism makes sure that both, connecting and mounting, is done properly and reliably.

Contact

Dirk Träger

Dirk Traeger


Related News

RJ45 Modules for 25 Gigabit Ethernet are Future-ready and Offer Maximum Investment Protection

RJ45 module 25G

Category 6A RJ45 modules can transmit up to 10 Gigabits per second. However the amount of data that has to be transmitted rises continually. Cat. 6A…

Read more

RJ45 Coupler and Patch Cord for Smart Metering

Smart Metering

The law to restart the digitalisation of the energy transition stipulates the use of smart metering systems and the associated deadlines in Germany,…

Read more

Stagger Wires Before Inserting them into the Wire Manager

Staggered wires can be inserted much easier and quicker into the wire manager. This saves a lot of time.

Read more

Straighten Wires Before Inserting them into the Wire Manager

Straighten Wires

Many IT projects are on a tight schedule. Clever ways of terminating the wires save time. The old proverb “small cause, big effect” proves true. When…

Read more