Description of the Series/Product Category
Notice: The following information refer to the series/product category as a whole. Please see the specific datasheet for specific technical information of a particular product.
Modern industrial and building wiring envisions linking the office network with the manufacturing network andits subordinate production cells and machinery. The applicable standard for this, ISO/IEC 24702 resp. EN 50173-1 and -3, are intended for situations with a high level of bidirectional traffic between the administration and manufacturing areas whereby realtime transmissions with high security, 100% availability and simultaneous high investment security must all be guaranteed. The increasing interconnection of machinery, equipment and measuring instruments in the production area using connectors already known from office wiring applications demands that these be adapted to the higher stresses presented by the contamination-prone, rough industrial environment. Aside from a variety of RJ45, IP67 M12 D- and X-coded connectors, Telegärtner therefore also offers designs for connecting glass and polymer fibres in order to meet this challenge.
Performance characteristics
Cat.6A acc. to IEC 60603-7-51
Cat.6A re-embedded tested acc. to IEC 60512-27-100
link certificate: Class EA acc. to ISO/IEC 11801
10 Gigabit-Ethernet compliant (IEEE 802.3an)
overbending protection: ≥750 mating cycles with RJ45/RJ11/RJ12 plugs
suitable for PoE+ acc. to IEEE 802.3at
suitable for switching programs from several manufacturers with design capable faceplate AMJ-S Up/0 flex
integrated strain relief for cable O.D. to 9 mm
universal, world-wide available installation dimension for mounting cut-outs: 19.3 x 14.7 mm
universal, world-wide available installation dimension for mounting cut-outs: 19.3 x 14.7 mm
AMJ-S DD: with integrated protection against damage to the contacts by automatic disconnection of the plug connection
Mechanical attributes
Insertion force |
≤ 30 N
|
---|
Life (mating cycles RJ45, RJ12, RJ11) |
≥ 750
|
---|
Cu-Conductor diameter: solid |
0.41 - 0.64 mm AWG 26/1 - AWG 22/1
|
---|
Cu-Conductor diameter: stranded |
0.46 - 0.76 mm AWG 27/7 - AWG 22/7
|
---|
Core Diameter |
0,9 - 1,6 mm
|
---|
Reusable IDC for AWG 22/1 and AWG 22/7 |
≤4 cycles
|
---|
Reusable IDC für AWG 23/1 - AWG 26/1 |
≤10 cycles
|
---|
Reusable IDC for AWG 24/7 - 27/7 |
≤10 cycles
|
---|
Cable diameter |
max. 9 mm
|
---|
Material: housing |
zinc diecast
|
---|
Material: insulating housing |
-
|
---|
Material: snap-fit |
phosphor bronze tinned
|
---|
Material: shield |
German silver
|
---|
Material: contact IDC termination |
CuNi2Si
|
---|
Material: insulators |
PC UL94 V0
|
---|
Material: IDC termination finish |
min. 3-6 µm Sn
|
---|
Material: PCB |
FR4
|
---|
Material: PCB finish |
chem. tin-plated
|
---|
Material: contact spring |
phosphor bronze tinned
|
---|
Material: contact spring finish |
min. 0,8 µm (µin) Au on 1,2 µm (50µin) Ni
|
---|
Material: cable clamp |
PC UL94 V0
|
---|
Durability (Matings) |
≥ 750
|
---|
Reusable IDC for AWG 22/1 |
≤10 cycles
|
---|
Reusable IDC for AWG 22/7 |
≤10 cycles
|
---|
Reusable IDC for AWG 24/7 - AWG 26/7 |
≤10 cycles
|
---|
Colour coding |
TIA 568 A
|
---|
Reusable contacts |
≤10 cycles
|
---|
Material: contacts |
Federstahl
|
---|
Material: jack housing |
zinc diecast
|
---|
Material: housing finish |
CuSnZn
|
---|
Material: contacts |
phosphor bronze tinned
|
---|
Material: contact finish |
min. 0,8 µm Au on 1,2 µm Ni
|
---|
Thermal and climatic attributes
UL |
E244889
|
---|
Temperature range [°C] |
-40/ 70
|
---|
Elecrical attributes
Contact resistance |
≤ 20 mΩ
|
---|
Insulation resistance |
≥ 500 MΩ
|
---|
Voltage proof: contact-contact |
≥ 1000 V, DC
|
---|
Voltage proof: contact-shield |
≥ 1500 V, DC
|
---|
Current carrying capacity at 50°C |
1 A
|
---|
PoE+ acc to IEEE 802.3at |
fulfilled
|
---|
PoE according to IEEE802.3af |
Adequate for 4 Pair Power over Ethernet
|
---|
Transmission properties
Category 6^A (Component) |
ISO/IEC 11801, DIN EN 50173-1
|
---|
Class E^A (Permanent Link) |
ISO/IEC 11801, DIN EN 50173-1
|
---|
Class E^A (Channel) |
ISO/IEC 11801, DIN EN 50173-1
|
---|
Class E (Channel with Coupler Cat.6) |
-
|
---|
Class D (Channel with Coupler Cat.5e) |
-
|
---|
Gigabit Ethernet acc. to IEEE 802.3 |
fulfilled
|
---|
10 Gigabit Ethernet acc. to IEEE 802.3an |
fulfilled
|
---|
Norms
Connectors |
IEC 60603-7-51
|
---|
Degrees of protection provided by enclosures (IP code) |
IEC 60529
|
---|
Custom-designed cabling systems |
ISO/IEC 11801; EN 50173-1; ISO/IEC 24702; IEC 61918
|
---|
Generic cabling systems |
PROFINET Installation Guideline
|
---|
Environmental requirements
Ambient temperature |
-40° C to +85° C
|
---|