Description of the Series/Product Category
Notice: The following information refer to the series/product category as a whole. Please see the specific datasheet for specific technical information of a particular product.
Performance characteristics
Cat.6A acc. to IEC 60603-7-51
Cat.6A re-embedded tested acc. to IEC 60512-27-100
link certificate: Class EA acc. to ISO/IEC 11801
10 Gigabit-Ethernet compliant (IEEE 802.3an)
overbending protection: ≥750 mating cycles with RJ45/RJ11/RJ12 plugs
suitable for PoE+ acc. to IEEE 802.3at
integrated strain relief for cable O.D. to 9 mm
universal, world-wide available installation dimension for mounting cut-outs: 19.3 x 14.7 mm
Mechanical attributes
Insertion force |
≤ 30 N
|
---|
Life (mating cycles RJ45, RJ12, RJ11) |
≥ 750
|
---|
Cu-Conductor diameter: solid |
0.41 - 0.64 mm AWG 26/1 - AWG 22/1
|
---|
Cu-Conductor diameter: stranded |
0.46 - 0.76 mm AWG 27/7 - AWG 22/7
|
---|
Core Diameter |
0,9 - 1,6 mm
|
---|
Reusable IDC for AWG 22/1 and AWG 22/7 |
≤4 cycles
|
---|
Reusable IDC für AWG 23/1 - AWG 26/1 |
≤10 cycles
|
---|
Reusable IDC for AWG 24/7 - 27/7 |
≤10 cycles
|
---|
Cable diameter |
max. 9 mm
|
---|
Material: housing |
zinc diecast Ni plated
|
---|
Material: insulating housing |
-
|
---|
Material: snap-fit |
spring steel
|
---|
Material: shield |
German silver
|
---|
Material: insulators |
PC UL94 HB
|
---|
Material: PCB |
FR4 UL94 V0
|
---|
Material: PCB finish |
chem. tin-plated
|
---|
Material: contact spring |
gold plated
|
---|
Material: contact spring finish |
min. 0,8 µm (µin) Au on 1,2 µm (50µin) Ni
|
---|
Material: contact IDC termination |
bronze tinned
|
---|
Material: IDC termination finish |
min. 3-6 µm (120-240 µin) Sn
|
---|
Material: cable clamp |
PC UL94 V0
|
---|
Material: wire pair presorting |
PC UL94 HB white
|
---|
Material: shield |
German silver
|
---|
strain relief |
PC UL94 V0
|
---|
Thermal and climatic attributes
Electrical attributes
Contact resistance |
≤ 20 mΩ
|
---|
Insulation resistance |
≥ 500 MΩ
|
---|
Voltage proof: contact-contact |
≥ 1000 V, DC
|
---|
Voltage proof: contact-shield |
≥ 1500 V, DC
|
---|
Current carrying capacity at 50°C |
1 A
|
---|
PoE+ acc to IEEE 802.3at |
Adequate for Power over Ethernet+
|
---|
PoE according to IEEE802.3af |
Adequate for 4 Pair Power over Ethernet
|
---|
Transmission properties
Category 6^A (Component) |
ISO/IEC 11801, DIN EN 50173-1
|
---|
Class E^A (Permanent Link) |
ISO/IEC 11801, DIN EN 50173-1
|
---|
Class E^A (Channel) |
ISO/IEC 11801, DIN EN 50173-1
|
---|
Class E (Channel with Coupler Cat.6) |
-
|
---|
Class D (Channel with Coupler Cat.5e) |
-
|
---|
Gigabit Ethernet acc. to IEEE 802.3 |
fulfilled
|
---|
10 Gigabit Ethernet acc. to IEEE 802.3an |
fulfilled
|
---|
Norms
Connectors |
IEC 60603-7-51
|
---|
Degrees of protection provided by enclosures (IP code) |
IEC 60529
|
---|
Environmental requirements
Ambient temperature |
-40° C to +85° C
|
---|
Protection against particulate ingress |
IP2X
|
---|
Protection against water / immersion |
IPX0
|
---|