homeapartmentpencilmagic-wanddroplighterpoopsunmooncloudcloud-uploadcloud-downloadcloud-synccloud-checkdatabaselockcogtrashdiceheartstarstar-halfstar-emptyflagenvelopepaperclipinboxeyeprinterfile-emptyfile-addenterexitgraduation-hatlicensemusic-notefilm-playcamera-videocamerapicturebookbookmarkuserusersshirtstorecarttagphone-handsetphonepushpinmap-markermaplocationcalendar-fullkeyboardspell-checkscreensmartphonetabletlaptoplaptop-phonepower-switchbubbleheart-pulseconstructionpie-chartchart-barsgiftdiamondlineariconsdinnercoffee-cupleafpawrocketbriefcasebuscartrainbicyclewheelchairselectearthsmilesadneutralmustachealarmbullhornvolume-highvolume-mediumvolume-lowvolumemichourglassundoredosynchistoryclockdownloaduploadenter-downexit-upbugcodelinkunlinkthumbs-upthumbs-downmagnifiercrossmenulistchevron-upchevron-downchevron-leftchevron-rightarrow-uparrow-downarrow-leftarrow-rightmovewarningquestion-circlemenu-circlecheckmark-circlecross-circleplus-circlecircle-minusarrow-up-circlearrow-down-circlearrow-left-circlearrow-right-circlechevron-up-circlechevron-down-circlechevron-left-circlechevron-right-circlecropframe-expandframe-contractlayersfunneltext-formattext-format-removetext-sizebolditalicunderlinestrikethroughhighlighttext-align-lefttext-align-centertext-align-righttext-align-justifyline-spacingindent-increaseindent-decreasepilcrowdirection-ltrdirection-rtlpage-breaksort-alpha-ascsort-amount-aschandpointer-uppointer-rightpointer-downpointer-left

Are keystone modules standardized?

Are keystone modules standardizes? Do modules of one manufacturer fit into the module carriers of another manufacturer?

 

Answer: The keystone format is standardized by IEC 60603-7. The most important dimensions and the tolerances that go with them are specified by this standard. However there are different designs of module carriers and faceplates available and do modules of one manufacturer do not necessarily fit into the modules carriers and faceplates of another manufacturer. Compatibility lists show which modules fit into which module carrier and faceplate. Such a list can be downloaded from the Telegärtner website as well as lists for module carriers of various floor boxes.

 

Nobody knows everything. A comprehensive topic like IT cabling inevitably raises questions. This column gives answers to questions which reached Telegärtner’s Technical Helpdesk and which we consider interesting for everyone. Please do not hesitate to send us your questions, we will be happy to answer them. The questions will be published anonymously, of course.

Contact

Dirk Träger

Dirk Traeger


Related News

Che cos'è la lucidatura UPC e qual è la differenza tra PC, UPC e APC?

APC Connector

Che cos'è la lucidatura UPC e qual è la differenza tra la lucidatura UPC e quella PC o APC?

Per saperne di più

Is there a uniform APC polishing angle?

APC COnnector

Is there a uniform APC polishing angle?

Per saperne di più

Cosa sono gli adattatori esagonali?

Connettore duplex MDC e adattatore esagonale

Cosa sono gli adattatori esagonali e qual è la differenza tra duplex, quad e hex?

Per saperne di più

Che cos'è la lucidatura UPC e qual è la differenza tra PC, UPC e APC?

Connettore in fibra ottica

Che cos'è la lucidatura UPC e qual è la differenza tra la lucidatura UPC e quella PC o APC?

Per saperne di più