MPO/MTP® APC FanOut module OS2; 6x LC duplex adaptor; 12x LC/APC FanOut
MPO/MTP® APC FanOut module OS2; 6x LC duplex adaptor; 12x LC/APC FanOut
Technical attributes
Article name | FO-M std 3/7 fom 6 LCD/A OS2 MPO12/Am |
---|---|
Fiber type | E9/125 OS2 |
Adaptors | LC Duplex |
Number of Adaptors | 6 |
Connector type | 1. Seite 1xMPO APC; 2. Seite 12xLC APC |
Housing Colour | MPO APC: green; LC/APC: green |
Description of the Series/Product Category
Notice: The following information refer to the series/product category as a whole. Please see the specific datasheet for specific technical information of a particular product.
The pre-term MPO/MTP® cabling system is the future-proof and economical solution for fiber optic networks from 10 Mbps to 100 Gbps according to EN 50173, EN50174, ISO/IEC 24764:2010 and ANSI/TIA-568-C.0. Telegärtner offers components according to connectivity method A as a standard, with identical MPO modules on either side of a link and 1:1 trunk cables. Components for connectivity methods B and C are also available.
Performance characteristics
Customer specific lengths avaliable using the TICNET configurator at www.telegaertner.com/ticnet
Low insertion loss components on request
Connectivity method A; type B and C also available
Mechanical attributes
Fiber structure: Primary coating | Acrylate, Ø 250 ±15 µm |
---|---|
Cable structure: Dimensions | Single fiber: 0.9 mm |
Bending radius | Single fiber: min. 30 mm |
Mating Face | male (female on request) |
Thermal and climatic attributes
Operating temperature in °C | -5 / 55 |
---|
Optical attributes
Polarity | Type A (Type B, C on request) |
---|---|
Life | ≥500 (MPO); ≥1000 (SC/LC) |
Insertion loss with fiber 9/125 | MPO APC: <0.7 (typ. 0.25) dB; LC/SC: <0.4 dB |
Insertion loss with fiber 50/125 | MPO PC: <0.5 (typ. 0.2) dB; LC/SC: <0.3 dB |
Return loss: Singlemode APC | MPO: >60 dB; LC/SC: >60 dB |
Return loss: Singlemode PC | LC/SC: >40 dB |
Return Loss: Multimode PC | MPO: >30 dB; LC/SC: >30 dB |