homeapartmentpencilmagic-wanddroplighterpoopsunmooncloudcloud-uploadcloud-downloadcloud-synccloud-checkdatabaselockcogtrashdiceheartstarstar-halfstar-emptyflagenvelopepaperclipinboxeyeprinterfile-emptyfile-addenterexitgraduation-hatlicensemusic-notefilm-playcamera-videocamerapicturebookbookmarkuserusersshirtstorecarttagphone-handsetphonepushpinmap-markermaplocationcalendar-fullkeyboardspell-checkscreensmartphonetabletlaptoplaptop-phonepower-switchbubbleheart-pulseconstructionpie-chartchart-barsgiftdiamondlineariconsdinnercoffee-cupleafpawrocketbriefcasebuscartrainbicyclewheelchairselectearthsmilesadneutralmustachealarmbullhornvolume-highvolume-mediumvolume-lowvolumemichourglassundoredosynchistoryclockdownloaduploadenter-downexit-upbugcodelinkunlinkthumbs-upthumbs-downmagnifiercrossmenulistchevron-upchevron-downchevron-leftchevron-rightarrow-uparrow-downarrow-leftarrow-rightmovewarningquestion-circlemenu-circlecheckmark-circlecross-circleplus-circlecircle-minusarrow-up-circlearrow-down-circlearrow-left-circlearrow-right-circlechevron-up-circlechevron-down-circlechevron-left-circlechevron-right-circlecropframe-expandframe-contractlayersfunneltext-formattext-format-removetext-sizebolditalicunderlinestrikethroughhighlighttext-align-lefttext-align-centertext-align-righttext-align-justifyline-spacingindent-increaseindent-decreasepilcrowdirection-ltrdirection-rtlpage-breaksort-alpha-ascsort-amount-aschandpointer-uppointer-rightpointer-downpointer-left

Fiber optic connector grades compared to GHMT PVP Level 2

20.02.2024 | What’s the difference between fiber optic connector grades specified by IEC 61753-1 and GHMT PVP Level 2?

 

The article  “GHMT Certification“ focused on the performance grades of fiber optic connectors specified by IEC 61753-1. The independent test lab GHMT AG specifies three different quality levels in their PREMIUM Verification Program (PVP) with Level 1 being the highest level of them.

 

In many projects, GHMT PVP Level 2 is an optimum of technically demanding specifications and cost-effectiveness.

The specifications of Level 2 are:

  • attenuation max. 0.25 dB
  • return loss min. 45 dB for connectors with a straight tip (PC)
  • return loss min. 60 dB for connectors with an angled tip (APC)

 

The specs recognize no exception, all connectors under test have to meet the specs.

 

IEC 61753-1:2019-10 specifies for the attenuation of singlemode fiber connectors among other classes

  • class B: max. 0.12 dB mean, max. 0.25 dB for a minimum of 97 % of the connections
  • classe C: max. 0.25 dB mean, max. 0,5 dB for a minimum of 97 % of the connections

 

and regarding return loss among others

  • class 1: min. 60 dB mated and min. 55 dB unmated
  • class 2: min. 45 dB

 

The specifications of PVP Level 2 thus correspond roughly to the connctor grades

  • B2 for singlemode connectors with a straight tip (PC)
  • B1 for singlemode connectors with an angled tip (APC)

 

Mean value according to class B is more strict but allows deviations. PVP Level 2 recognizes no exceptions.

 

Author:

Dirk Traeger

Technical Solutions Manager DataVoice