module for shielded and unshielded installation cables, with mounting rail adaptor
module for shielded and unshielded installation cables, with mounting rail adaptor
Technical attributes
Article name | CU-CM VM8-8 C7A AWG26-22 w/DinRadapt |
---|---|
Remarks | module for shielded and unshielded installation cables, with mounting rail adaptor |
Colour | black |
Description of the Series/Product Category
Notice: The following information refer to the series/product category as a whole. Please see the specific datasheet for specific technical information of a particular product.
Performance characteristics
connection via LSA Plus terminals on a common PCB
colour coding acc. to EIA/TIA 568A and B
connection of 4-pair shielded/unshielded installation and patch cords from AWG 27-22
pairs can be brought directly up to the terminal without untwisting the pairs
secure shielded contact using screw-on terminals directly on the PCB
variable cable feeds
cable strain relief using commercially available cable ties (VM 8-8 Cat.7A)
tool-free installation of shielding cover made of stainless steel (19" and wall mount version)
surface mount (AP) type: incoming and outgoing cables in the same direction
surface mount, 19", and basic (for loose connection) version: incoming and outgoing cables offset by 180 degrees
bonding connection option directly on the PCB (M4 screw)
EMC compatible in accordance with DIN EN 61000-6-1 and 61000-6-2
Mechanical attributes
Conductor diameter | 0,41 - 0,64 mm AWG 26/1 - AWG 22/1 |
---|---|
Core Diameter | 0,7 - 1,6 mm |
Material: housing | ABS non halogen, UL94 V0 black |
Material: shield | EMC plating aluminium |
Material: PCB | FR4 |
Material: PCB finish | Cu 35/35 zinc-plated |
Material: cable ties | PA 6.6 UL94 V2 |
Thermal and climatic attributes
Temperature range [°C] | -40/ 70 |
---|
Elecrical attributes
Voltage proof: contact-contact | ≥ 1000 DC |
---|---|
Voltage proof: contact-shield | ≥ 1500 DC |
Current carrying capacity at 50°C | 1 A |
Transmission properties
Next: at 100 MHz | 75.0 dB min. |
---|---|
Next: at 250 MHz | 68.3 dB min. |
Next: at 600 MHz | 60.7 dB min. |
Next: at 1 GHz | 57.8 dB |
Return loss: default values at 100 MHz | ≥ 28,00 dB |
Return loss: default values at 250 MHz | ≥ 20,00 dB |
Return loss: default values at 600 MHz | ≥ 12,40 dB |
Rückflussdämpfung: Vorgabewerte bei 1 GHz | ≥ 10,00 dB |
Insertion loss: default values at 100 MHz | 0.2 dB max. |
Insertion loss: default values at 250 MHz | 0.32 dB max. |
Insertion loss: default values at 600 MHz | 0.49 dB max. |
Insertion loss at 1 GHz | 0.63 dB |
Contact resistance: default values | 200 mΩ max. |
Next: typical values at 100 MHz | 82.3 dB |
Next: typical values at 250 MHz | 77.1 dB |
Next: typical values at 600 MHz | 67.1 dB |
Next: typ. value at 1 GHz | 58.9 dB |
Return loss: typical values at 100 MHz | 28,9 dB |
Return loss: typical values at 250 MHz | 26,5 dB |
Return loss: typical values at 600 MHz | 17,9 dB |
Return loss typ. values at 1 GHz | 15,6 dB |
Insertion loss: typical values at 100 MHz | 0.05 dB |
Insertion loss: typical values at 250 MHz | 0.1 dB |
Insertion loss: typical values at 600 MHz | 0.3 dB |
Insertion loss typ. value at 1 GHz | 0.43 dB |
Return loss: typical values | < 10 mΩ |
Cat.7^A | Kategorie 7A acc. to ISO/IEC 11801; EN 50173-1 |